Investigation of repeated economiser tube failures of a 135 tph cold cyclone CFB boiler – a case study

Jump To References Section

Authors

  • ,IN

DOI:

https://doi.org/10.18311/ijprvd/2021/28066

Keywords:

Economiser, tube failure, cyclone, CFB boiler, mechanism

Abstract

There were quick and successive failures of economiser tubes in a four years old cold cyclone circulating fluidised bed 135 tph boiler in a short span of three months. Advance inspection and failure analysis, change in operational practices were used to get the boiler running at full load at the earliest possible time. This paper presents details of the process of inspection, maintenance, operation and failure investigation carried out for the economiser tubes of the boiler. The failure of the economiser tubes was due to external corrosion of the tubes furnace fire side due to presence of sulphur in coal, accompanied by localised erosion by high levels of alpha-quartz in coal ash.

Downloads

Download data is not yet available.

Metrics

Metrics Loading ...

Downloads

Published

2021-07-02

How to Cite

Bhattacharya, C. (2021). Investigation of repeated economiser tube failures of a 135 tph cold cyclone CFB boiler – a case study. Indian Journal of Power and River Valley Development, 71(5&6), 73–81. https://doi.org/10.18311/ijprvd/2021/28066
Received 2021-07-02
Accepted 2021-07-02
Published 2021-07-02

 

References

Mohammad A. Malek, Ph.D., P.E.(2007): Heating Boiler Operator's Manual: Maintenance, Operation, and Repair. Appendix B: Maximum Allowable Stress Values for Ferrous Materials, Chapter (McGraw-Hill Professional).

O&M Manual of 135 TPH Single Drum Coal Fired Circulating Fluidised Combustion Water Tube Boiler with Cold Cyclone Technology (Make Thyssenkrupp Industries India Ltd.)

Tube sample test report of M/s Indicative Consultant India dated 03.11.16

Boiler Slag/scale sample test report of M/s Indicative Consultant India dated 31.10.16

Fired fuel mix sample test report of M/s Indicative Consultant India dated 22.9.16

Bhattacharya, C. (2000): "Minimizing Erosion – Factor Which Costs the active Life of Atmospheric Fluidised Bed Boilers” Proceedings of National Conference on material issues of Fluidized Bed Boilers; pp.33-44, 2-3.12.2000; NPTI–ER/Durgapur, Dalhousie University & Greenfield Research Inc. Canada; Durgapur, W. Bengal.

Bhattacharya, C.; Sarkar, H. S.(2003): "Economic Assessment of Utilization of Beneficiated Indian Power Coal for Thermal Power Generation” (April 2003); National Symposium (SRP-2003) CMERI (CSIR)/Durgapur/INDIA .(Abstracted PP: 46-47).

Bhattacharya, C.; Saha, B.; Manna, J.; Bera, S. (2007): "Impact of Boiler Tube failure in Power Pricing & Profitability” Proceedings of National Conference on Enhancement of Plant Availability by Life Assessment & Condition Monitoring (LACOM- 2007), 19-20.12.2007; CMERI (CSIR), Durgapur.

Course material for Onsite Workshop on "Boiler Tube Failure & its Remedy” 18-19.12.2006; for DVC; CTPS, Chandrapura –Edited by Chittatosh Bhattacharya.

Indian Boiler Regulation 1960 (As amended 2004) Published Version 2007.

ASME PTC 4.0 2008 Fired Steam Generators