A Numerical Study on the Fire Induced Collapse of a Real Life Warehouse Structure Based on Post-Fire NDT Results
DOI:
https://doi.org/10.18311/jmmf/2023/35443Keywords:
Finite Element Analysis, Fire-Induced Damage, Non-Destructive Test, Temperature Load, WarehouseAbstract
Fires being a Low-Probability High-Consequence problem, can have a big impact on the structures due to their occurrence; irrespective of the construction materials. Even, the damage might lead to structural collapse. Such failures have warned to check the impact of fire on structural elements, which is frequently overlooked in popular design guidelines. Warehouses are used for the storage of different types of commodities; however, the vulnerability of these structures during fire event depends on the storage materials and other factors. Such a warehouse with steel roof trusses supported over Reinforced Cement Concrete (RCC) frame, located at Kolkata, suffered one of such severe fire-induced damage; and the roof truss system along with some portions of the brick masonry walls got totally collapsed. The information about the structure including its design data is presented along with the site observations after the fire incident, and the results of various Non-Destructive Tests (NDTs) performed over RCC frame elements. A severe fire of 8-hour duration led to a huge increase in temperature, which is considered to be the main reason of the progressive collapse of the entire warehouse structure. To better understand the failure of members due to temperature load, the present study aims to analyse a numerical model of the damaged structure in the Finite Element (FE) Framework. The roof truss, RCC frames and brick masonry walls are modelled; and temperature load is applied along with self-weight load to check the effect of incremental temperature on various structural responses of the warehouse. The temperature-dependent material properties are considered in the analyses; as applicable. Results have shown that there is a significant effect of temperature load, which gets worse with increasing temperature. The connection between roof truss and columns also contributes to the extent of damage in the truss supported over RCC frames; as evident from the numerical analysis. The present study seems to present a clear view about the fire-induced structural collapse of a real-life warehouse structure
Downloads
Metrics
Downloads
Published
How to Cite
Issue
Section
License
This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
References
Basu DJ, Acharjee D, Bandyopadhyay D. Fire resistance of RCC T-beam under cyclic load: A numerical study. In: Lecture Notes in Civil Engineering. Singapore: Springer Nature Singapore. 2023; 1047-60. https://doi. org/10.1007/978-981-19-1862-9_67. DOI: https://doi.org/10.1007/978-981-19-1862-9_67
Živanić D, Ilanković N, Zelić A. Fire Safety Measures in Warehouses. 16th International Conference of Occupational Health and Safety. 2009.
Warehouse structure fires. Nfpa.org. [cited 2023 Aug 24]. Available from: https://www.nfpa.org/ News-and-Research/Data-research-and-tools/Buildingand-Life-Safety/Warehouse-Structure-Fires
Eslami M. Forensic Investigation of Fire-Induced Collapse of a Steel Building. Structures Congress. 2022. https://doi.org/10.1061/9780784484180.027. DOI: https://doi.org/10.1061/9780784484180.027
Ambroziak A, Piotrkowski P, Heizig T. Assessment of technical condition and repair of steel structure elements on the example of fire damage in a warehouse building. In: MATEC Web of Conferences, ICSF 2019. 2019. https://doi.org/10.1061/9780784484180.027. DOI: https://doi.org/10.1051/matecconf/201928402001
Basu DJ, Acharjee D, Bandyopadhyay D. Numerical study on fire resistance behavior of EPS sandwich panels. Mater Today. 2022; 60:459-65. https://doi.org/10.1016/j. matpr.2022.01.319. DOI: https://doi.org/10.1016/j.matpr.2022.01.319
Prakash PR, Srivastava G. Efficient three-dimensional nonlinear Thermo-mechanical analysis of structures subjected to fire. Procedia Eng. 2017; 210:504-11. https:// doi.org/10.1016/j.proeng.2017.11.107. DOI: https://doi.org/10.1016/j.proeng.2017.11.107
Sakji S, Mege R, Leblond P. Kinematics of the collapse of a warehouse structure under fire. In: WIT Transactions on The Built Environment. Southampton UK: WIT Press; 2017. https://doi.org/10.2495/SAFE170081 DOI: https://doi.org/10.2495/SAFE170081
Li Y, Lu X, Guan H, Ying M, Yan W. A case study on a fire-induced collapse accident of a reinforced concrete frame-supported masonry structure”. Fire Technology. 2016. https://doi.org/10.1007/s10694-015-0491-0. DOI: https://doi.org/10.1007/s10694-015-0491-0
IS 516 (Part 5/Sec 1). Non-Destructive Testing of Concrete-Ultrasonic Pulse Velocity Testing. 2018.
IS 516 (Part 5/Sec 4). Non-Destructive Testing of Concrete-Rebound Hammer Test. 2020.
Bakhteri J, Makhtar AM, Sambasivam S. Finite element modelling of structural clay brick masonry subjected to axial compression. J Teknol [Internet]. 2012. https://doi. org/10.11113/jt.v41.698 DOI: https://doi.org/10.11113/jt.v41.698
Teja PRR. Studies on Mechanical Properties of Brick Masonry. M. Tech (Research) Thesis, National Institute of Technology Rourkela, Dept. of Civil Engineering. India; 2015.
Wikipedia.org. [cited 2023 Aug 23]. Available from: https://en.wikipedia.org/wiki/Tin
IS 875 (Part 3). Code of Practice for Design Loads (Other than Earthquake) For Buildings and Structures. Part 3: Wind Loads. Third Revision. 2015.
Trifone L. A Study of the Correlation between Static and Dynamic Modulus of Elasticity on Different Concrete Mixes of Elasticity on Different Concrete Mixes”. United States; 2017.
IS 800. General Construction in Steel- Code of Practice. Third Revision. 2007.
IS 875 (Part 1). Code of Practice for Design Loads (Other than Earthquake) For Buildings and Structures. Part 1: Dead Loads-Unit Weights of Building Materials and Stored Materials. Second Revision. 1987.
IS 875 (Part 2). Code of Practice for Design Loads (Other than Earthquake) For Buildings and Structures. Part 2: Imposed Loads. Second Revision. 1987.
IS 1893 (Part 1). Criteria for Earthquake Resistance design of Structures, Part-I General provision and buildings. Sixth Revision. 2016.
IS 875 (Part 5). Code of Practice for Design Loads (Other than Earthquake) For Buildings and Structures. Part 3: Wind Loads. Second Revision. 1987.
Botte W, Caspeele R. Post-cooling properties of concrete exposed to fire. Fire Safety J. 2017; 92:142-50. https://doi. org/10.1016/j.firesaf.2017.06.010. DOI: https://doi.org/10.1016/j.firesaf.2017.06.010
Lou G, Wang C, Jiang J, Jiang Y, Li G-Q. Fire-induced progressive collapse of 3D steel portal frames. Procedia Eng. 2017; 210: 537-43. https://doi.org/10.1016/j.proeng.2017.11.111 DOI: https://doi.org/10.1016/j.proeng.2017.11.111
IS 456. Plain and Reinforced Concrete- Code of Practice. Fourth Revision. 2000.
Galvez JC, Reyes E, Casati MJ, Sancho JM, Planas J, Cendon DA. Mixed mode fracture of brickwork masonry. Fracture of Nano and Engineering Materials and Structures. Dordrecht: Springer Netherlands; 2008; 1359-60. https://doi.org/10.1007/1-4020-4972-2_675. DOI: https://doi.org/10.1007/1-4020-4972-2_675