Sensitivity Variation Of A Flowmeter With Varying Shapes Of The Target
DOI:
https://doi.org/10.18311/jmmf/2022/30680Keywords:
Flow rate, tensor flow, coefficient of discharge, target flow.Abstract
Accurate measurement of flow rate of fluids is known to be an essential requirement with various industrial applications. Flowmeters have been realized with different sensing methodologies; among them the target flowmeter/ drag flowmeter has been in the mainstay for decades. In the present research work, the variation in the sensitivity of a target flow meter with varying shapes of the targets is evaluated by experimental results and simulation. Flow rates of water between 0 lt/s to 1 lt/s is considered for sensitivity evaluation of the target flow meter with target being flat faced, V faced and curved faced. The excellent agreement between the experimental results and simulation illustrates the efficacy of the analytics carried out in the present study.
Downloads
Metrics
Downloads
Published
How to Cite
Issue
Section
References
M. A. Rahman, A. Amirfazli, T. Heidrick, and B. A. Fleck, (2007): “A review on advanced two-phase gas/ liquid flow measurement techniques,” in Proceedings of the International Conference on Mechanical Engineering.
A. Nour, Maha; M. Hussain, Muhammad. (2020): “A Review of the Real-Time Monitoring of Fluid- Properties in Tubular Architectures for Industrial Applications” Sensors 20, no. 14: 3907. https://doi.org/ 10.3390/s20143907
Baker RC, Morris MV. (1985): Positive-displacement meters for liquids. Transactions of the Institute of Measurement and Control. 1985;7(4):209-220. doi:10.1177/014233128500700405
Bunyamin et al, (2019): Challenges in Turbine Flow Metering System: An Overview”, J. Phys.: Conf. Ser. 1198 042010
Mattingly, G E. (1992): “The Characterization of a Piston Displacement-Type Flowmeter Calibration Facility and the Calibration and Use of Pulsed Output Type Flowmeters.” Journal of research of the National Institute of Standards and Technology vol. 97,5 (1992): 509-531. doi:10.6028/jres.097.023
J. C. Yuen and Z. Feng, (2000): “Monitoring free flaps using the laser Doppler flowmeter: Five-year experience,” Plast. Reconstr. Surg. 105(1), 55–61.
N. Qi, Y.-Z. Song, S.-M. Fu, and X.-L. Jiang, (2018): “Circuit design of ultrasonic flow sensor based on FPGA,” in Proceedings of the International Conference on Information Technology and Electrical Engineering 2018 (ICITEE 18).
£. Zaworski, M. Kowalski, and M. Zieliñski, (2011): “Application of FPGA devices to ultrasonic flowmeter,” Pomiary, Autom., Kontrola 57, 1511–1514.
W.-J. Zhu, K.-J. Xu, M. Fang, W. Wang, and Z.-W. Shen, (2016): “Mathematical modelling of ultrasonic gas flow meter based on experimental data in three steps,” IEEE Trans. Instrum. Meas. 65(8), 1726–1738.
N. T. Basse, “A review of the theory of Coriolis flowmeter measurement errors due to entrained particles,” Flow Meas. Instrum. 37, 107–118 (2014).
B. R. Binulal and J. Kochupillai, (2014): “Coriolis flow meter: A review from 1989 to 2014,” Int. J. Sci. Eng. Res. 5(7), 718–723.
Roger C. Baker, (1994): “Coriolis flowmeters: industrial practice and published information”, Flow Measurement and Instrumentation, Vol.5, Issue 4, October, Pages 229-246.